Pairs BS5308 Collective Screened twisted multi-pair sheild Instrument Cable

                            Pairs BS5308 Collective Screened twisted multi-pair sheild Instrument Cable

                            Pairs BS5308 Collective Screened twisted multi-pair sheild Instrument Cable

                            Pairs BS5308 Collective Screened twisted multi-pair sheild Instrument Cable

                            Pairs BS5308 Collective Screened twisted multi-pair sheild Instrument Cable

Pairs BS5308 Collective Screened twisted multi-pair sheild Instrument Cable

Pairs BS5308 Collective Screened twisted multi-pair sheild Instrument Cable,hongda,Electrical Equipment & Supplies,Wires, Cables & Cable Assemblies,Instrumentation Cables
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Henan, China (Mainland)
Brand Name:
hongda
Model Number:
instrument cable
Shielding:
Combination
Conductor Material:
Copper
Jacket:
PVC
Insulation Material:
XLPE
Model:
Instrument Cable
Type:
armored xlpe cable
model2:
insulated Instrument Cable
Packaging & Delivery
Packaging Details
coil or according to your require
Delivery Time
Shipped in 20 days after payment

Pairs BS5308  Collective Screened twisted multi-pair sheild Instrument Cable

 

Pairs BS5308 Instrument Cable Collective Screened

insulated cable

Standard of insulated cable:
It is manufacture under GB/T12706-2002 standard(The same as IEC60502).

 

Instrument Cable Application:

For use in installations designed to connect electrical instrumentation circuits and provide communication services in and around process plants. Suitable for direct burial applications.

Specification of instrument cable:

Instrument Cable Conductors:

0.5mm - class 5 flexible copper

0.75mm - class 5 flexible copper

1.5mm - class 2 stranded copper

Insulation: PE (Polyethylene)

Screen: CAM (Collective Aluminium Mylar)

Bedding: PE (Polyethylene)

Armour: SWA

Outer Sheath: PVC (Polyvinyl-Chloride)

Voltage Rating: 300/500volts

Temp. Rating: 65 C

Flexible  instrumentation multi-core cables about PVC insulated and twisted parallel cable

 

 

Standard: National Standard GB/T 5023; IEC60227

Rated Voltage: 300/300V;

 Construction: 1. annealed flexible copper conductor

                       2.PVC insulated 

 Application: used for electric appliance, electric tool, electric instruments and lighting, automatic system 


Application of insulated cable Instrument Cable :
It is used to transmit and distribute power on the power line of A. C. Rated voltage 0.6/1kV.

XLPE insulated electric cable Instrument Cable 0.6/1kv
norminalsectional area insulati-on thicknessheath thickness(mm)overal diameter of cable (mm)D.C resistance of conductor(km)                current rating
in air(A)direct in soil(A)
cuAlcuAlcuAl
1×1.50.71.56<=12.1<=12.130254535
1×40.71.57<=7.41<=7.4145356050
1×60.71.57<=3.08<=4.6155457055
1×350.91.512<=0.524<=0.868175140190150
1×5011.513<=0.387<=0.641210170225180
1×70

1

.1

1.514<=0.268<=0.443270215280225
1×951.11.516<=0.193<=0.320340275335270
1×1201.21.518<=0.153<=0.253400320380305
1×1501.4221<=0.124<=0.206460370425340
1×1851.6223<=0.0991<=0.164530415480375
1×2401.7225<=0.0754<=0.125625490555435
         
3×1.50.71.510<=12.1<=12.125253030
3×2.50.71.511<=7.41<=12.130253530
3×40.71.512<=4.61<=7.4140305040
        
Attention: We can provide more info than above data, if needed.The above are just some examples.

 



Using features of insulated cable Instrument Cable :
1. Rated voltage: Uo/U: 0.6/1kV
2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 160oC.
4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.

Model: insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable

 

Pairs BS5308 Collective Screened twisted multi-pair sheild Instrument CablePairs BS5308 Collective Screened twisted multi-pair sheild Instrument CablePairs BS5308 Collective Screened twisted multi-pair sheild Instrument CablePairs BS5308 Collective Screened twisted multi-pair sheild Instrument CablePairs BS5308 Collective Screened twisted multi-pair sheild Instrument Cable

welcome to inquire us  Instrument Cable